Elevator control panel for 16-floors SA-EB16 also known as a smart card elevator access control system. It is used to lift hierarchical control, personnel up and down the elevator access control system products. It can be used to meet building service management company or management personnel access lift more efficient and safer management needs. The system set up by the addition of all the cardholder to enter the floor carried out all floors access control. SA-EB16 status for different people with different floor privileges, you can specify a person who only can go to certain floors, certain floor or all floors, each floor through permissions management, there are some who can reach the floor, who can not reach some floors, and the controller may be authorized in accordance with time management.
- Home
- ShineACS Access Control Products
- Access Control System
- IP Access Controller Panel Kits For Door Access Control System.
- Elevator control panel for 16-floors SA-EB16
02 Details Information
- General Details
- Technical Info
- Download
General Details
- Without the express elevator controller authorized offline operation,
- An independent group of people can store 26,000data records with 100,000 readers so that all staffs have access to data recorded floor to be found.
- And the elevator Max to 16 floors, but can be extended with an expansion board supports up to 16 expansion board, and ultimately can manage a maximum of 32 floors
- Supports RS485 and TCP/IP communication methods.
- Providing two standard card reader interface, supporting
- WG26, WG34, WG44 reader or fingerprint device.
- All input/output of elevator controller energized dynamic protection and all relay outputs With transient over-voltage protection supports fire input linkage.
- Automatically search for and install a controller
- Remote open door, full card to open door
- Running stable monitoring(voltage input, watchdog, operating days)
- Timeframe management
- Limit the number of people inside the door and region
- Fire protection alarm
- Access authentication methods setting
- Anti-passback, interlock function
- Read card inside and outside to open door
- Video capture
Drawing:
Wiring Diagram
Technical Info
Mode | SA-EB16 |
Operating Mode | elevator controller, lockers access management |
Recognition Type | Em4100,Mifare,fingerprint, card, password |
Identification Information: | card, card with password, password, dual card identification, management card+user card to open |
Working Current: | 500mA ->Exclude card reader |
Drive Current: | <Each group 7A ->Following the dry battery contact(NO,NC software adjustable) |
Working voltage | DC10.8-14V,->Standard DC12V |
Operating temperature: | -25℃ to 70℃ |
Operating humidity | 10%-90%RH,no-condensation |
Punch Period: | Support ->64 hours |
Validity Period: | Support ->one day-100 years arbitrarily set |
Offline Operation | Support |
Extended Board: | 32-layer control group implementation capacity |
Card Capacity | 26K groups |
Data Capacity: | 100K |
Networking: | RS485 and TCP/IP, ->TCP/IP is optional |
Networking Equipment: | 127pcs |
Communication distance | RS485 networking is 1200m |
Transmission Frequency: | 19200 baud ->19200 8,1,n |
Data Retention: | 10 years,->off state stored for 10 year |
Transfer Methods: | Real-time, non-real-time |
Device Color: | Green |
Housing Material: | Control box with iron spray material |
Box Size: | 371mm*259mm*78mm |
Board Size: | 220mm*135mm*22mm |